Thyrotropin Thyroid Stimulating Hormone Measurement
from Thyroid

 


TSH Heterogeneity

 

TSH is a heterogeneous molecule and different TSH isoforms circulate in the blood and are present in the pituitary extracts used for assay standardization (Medical Research Council (MRC) 80/558).

Do you have any articles relating to measure response of tsh to thyroid supplementation. If so, please send to news@thyroidtalk.com

In the future, recombinant human TSH (rhTSH) preparations might be used as primary standards for standardizing TSH immunoassays.[198] Current TSH IMA methods use TSH monoclonal antibodies that virtually eliminate cross-reactivity with other glycoprotein hormones. These methods however, may detect epitopes of abnormal TSH isoforms secreted by some euthyroid individuals, as well as some patients with abnormal pituitary conditions. For example, patients with central hypothyroidism caused by pituitary or hypothalamic dysfunction, secrete TSH isoforms with abnormal glycosylation and reduced biological activity. These isoforms are measured as paradoxically normal or even elevated serum TSH concentrations by most methods.[195,197,199] Likewise, paradoxically normal serum TSH levels may be seen in patients with hyperthyroidism due to a TSH-secreting pituitary tumors, that appear to secrete TSH isoforms with enhanced biologic activity.[196,200,201]
Technical Problems

 

Technical problems, especially with the washing step, may result in falsely high TSH values.[202] Additionally, any interfering substance in the specimen (eg heterophilic antibodies, HAMA) that produces a high background or a false bridge between the capture and signal antibodies will create a high signal on the solid support that will be read out as a falsely high result [see Section-2C3].[203,202]
Methods for Detecting Interference with a TSH Result

 

The conventional laboratory approach to verifying an analyte concentration such as dilution may not always detect an interference problem. Since methods vary in their susceptibility to most interfering substances, the most practical way to test for interference is to measure the TSH concentration in the specimen using a different manufacturer's method, and to check for a significant discordance between the TSH values. When the variability of TSH measurements made on the same specimen with different methods exceeds expectations (>50% difference), interference may be present. Biologic checks may also be useful to verify an unexpected result. Inappropriately low TSH values could be checked by a TRH-stimulation test, which is expected to elevate TSH more than 2-fold (>/=4.0 mIU/L increment) in normal individuals.[204] In cases where TSH appears inappropriately elevated, a thyroid hormone suppression test (1mg L-T4 or 200µg L-T3, po) would be expected to suppress serum TSH more than 90% by 48 hours in normal individuals.

 